Resources / Online calculators

Your process calculations.
Right here.

Practical tools to prepare your projects and check orders of magnitude: flow, pipework, volumes, transfers and water heating.

No installation or account. Calculations stay in your browser; these tools neither send nor save your inputs.

01 / Resources / Online calculators

Convert a flow rate

Convert L/h, L/min and m³/h to compare line capacities.

Prefilled examples to adapt. Use a decimal point or comma, without thousands separators.

Enable JavaScript to use the calculator. Formulas and assumptions remain available alongside it.

Method and assumptions

1 m³/h = 1 000 L/h; 1 L/min = 60 L/h

Liquid volumetric flow only. Does not convert mass flow or normalised gas flow.

Results are rounded for display; assumptions and input accuracy limit actual precision.

02 / Resources / Online calculators

Pipe velocity and volume

Estimate average liquid velocity and volume in a full pipe.

Prefilled examples to adapt. Use a decimal point or comma, without thousands separators.

Enable JavaScript to use the calculator. Formulas and assumptions remain available alongside it.

Method and assumptions

A = π(D/1 000)²/4; V = A × L × 1 000; v = Q/(3 600 000 × A)

Full circular pipe, actual internal diameter D in mm, length L in m and flow Q in L/h. DN is not the internal diameter. Excludes bends and fittings; does not calculate pressure losses, pump pressure or cleaning effectiveness.

Pipe velocity guidelines

Transfer of low-viscosity liquids: around 1 to 2 m/s on the discharge side is an initial order of magnitude. Product properties, viscosity, pressure losses, foaming and product sensitivity may require a different velocity.

CIP of full pipework: a range of 1.5 to 3 m/s is commonly considered for low-viscosity cleaning solutions to strengthen mechanical action. This guideline does not directly apply to spray balls, filters or heat exchangers.

Velocity alone guarantees neither turbulence nor cleanliness. Diameter, viscosity, actual circulation in each branch, chemistry, temperature and time must be assessed. Pump flow and pressure are sized for the circuit; the protocol is validated on the installation.

Results are rounded for display; assumptions and input accuracy limit actual precision.

03 / Resources / Online calculators

Cylindrical tank volume

Calculate the internal volume of a straight cylindrical body from its diameter and height.

Prefilled examples to adapt. Use a decimal point or comma, without thousands separators.

Enable JavaScript to use the calculator. Formulas and assumptions remain available alongside it.

Method and assumptions

V(L) = π(D/1 000)² × (H/1 000) × 1 000/4; 1 hL = 100 L; 1 m³ = 1 000 L

D and H are internal dimensions in mm of the cylindrical body only. Excludes dished or conical ends, fittings and filling allowance. The result is not a guaranteed working volume.

Results are rounded for display; assumptions and input accuracy limit actual precision.

04 / Resources / Online calculators

Transfer time

Estimate the time needed to transfer a volume at constant flow.

Prefilled examples to adapt. Use a decimal point or comma, without thousands separators.

Enable JavaScript to use the calculator. Formulas and assumptions remain available alongside it.

Method and assumptions

t(min) = 60 × V(L)/Q(L/h)

Volume V in L and strictly positive flow Q in L/h. Excludes priming, stops and residual liquid. This is not the duration of a CIP cycle.

Results are rounded for display; assumptions and input accuracy limit actual precision.

05 / Resources / Online calculators

Water heating: energy and ideal time

Estimate sensible energy and ideal heating time for a volume of water.

Prefilled examples to adapt. Use a decimal point or comma, without thousands separators.

Enable JavaScript to use the calculator. Formulas and assumptions remain available alongside it.

Method and assumptions

E(kWh) = V(L) × 1 × 4,19 × (T₂ − T₁)/3 600; t(min) = 60E/P(kW)

Liquid water from 0 to 95 °C: approximate density 1 kg/L and constant heat capacity 4.19 kJ/(kg·K). Constant net power P transferred to water. Excludes losses, heating the tank and pipes, boiling or other fluids: actual time may be longer. This is not an installation sizing tool.

Results are rounded for display; assumptions and input accuracy limit actual precision.

Explained methods and clear assumptions.

These preliminary calculations help prepare a technical discussion. They do not validate a machine, a hygiene protocol or process performance.

Using the online calculators ↗

From calculation to your installation.

Results depend on your actual conditions. For process engineering or machine documentation, let us clarify your application together.