Tiko Tools

Water heating: energy and ideal time

Estimate sensible energy and ideal heating time for a volume of water.

← All tools

Water heating: energy and ideal time

Estimate sensible energy and ideal heating time for a volume of water.

Prefilled examples to adapt. Use a decimal point or comma, without thousands separators.

Enable JavaScript to use the calculator. Formulas and assumptions remain available alongside it.

Method and assumptions

E(kWh) = V(L) × 1 × 4,19 × (T₂ − T₁)/3 600; t(min) = 60E/P(kW)

Liquid water from 0 to 95 °C: approximate density 1 kg/L and constant heat capacity 4.19 kJ/(kg·K). Constant net power P transferred to water. Excludes losses, heating the tank and pipes, boiling or other fluids: actual time may be longer. This is not an installation sizing tool.

Results are rounded for display; assumptions and input accuracy limit actual precision.

Worked example

For 500 L of water heated from 20 to 60 °C with a net power of 12 kW: energy = 23.27778 kWh and ideal time = 116.3889 min. Heat losses and vessel heating are excluded.